High Precision IEC Standard AC 380V Gas Test Chamber Stainless Steel
Contact Person : Jack He
Phone Number : +86-13842409825
WhatsApp : +8613842409825
Minimum Order Quantity : | 1 set | Price : | $12000 >=1 Set |
---|---|---|---|
Delivery Time : | 35 work days | Payment Terms : | L/C, D/A, D/P, T/T, Western Union |
Supply Ability : | 10 sets per month |
Place of Origin: | Guangdong | Brand Name: | Envsin |
---|---|---|---|
Certification: | ISO CE | Model Number: | EQF |
Detail Information |
|||
Warranty: | 1 Year | Power: | Electronic |
---|---|---|---|
Gas Concentration: | 5ppm~30ppm | Gas Flowmeter: | H2S,SO2,NO2,Cl2 |
Wind Speed: | ≤1.7m/s | ||
High Light: | IEC60068-2-1 Gas Test Chamber,25ppm electronic Gas Test Chamber,25ppm Climatic Test Chamber |
Product Description
25ppm H2s No2 So2 Sulphur Dioxide Gas Corrosion Test Chamber
Our service:
Main Technical Parameters (Product Model:EQF2330)
|
||
Temp test
|
Temp range: 20℃~+45℃
|
Remark:
1. Test in accordance with IEC60068
under empty chamber condition (except indicated).
2. The test data of the water-cooled
test chamber are under the conditions that the water temperature is less than 28, the water pressure is between 0.3MPa and 0.6MPa, and the
water pressure difference between inlet and outlet is more than 0.2MPa.
|
Temp uniformity : ≤2.0℃ | ||
Temp deviation: ≤±2.0℃ | ||
Temp fluctuation: ≤±0.5℃ | ||
Temp rate:≥ 1℃/min | ||
Temp and humidity test
|
Temp control range: 20℃~+50℃ Humidity range: 50% RH~85% RH |
|
Humidity uniformity: ±5.0% RH | ||
Humidity deviation: +2.0%~ 3%RH( >75%RH)±5%R.H( ≤75%RH) | ||
Humidity fluctuation: ±5.0%RH | ||
Gas concentration | 5ppm~30ppm | |
The deviation of gas concentration in the chamber shall not exceed 10% of the set concentration,concentration uniformity deviation of 10% | ||
The empty chamber operation request meets the IEC60068-2-60 standard | ||
Gas concentration measurement | By calculating the volume ratio and then through the mass flowmeter measurement | |
On load capacity |
500W,The temperature can be stable, the chamber body is not deformed
|
|
Noise
|
Working noise ≤70dB ( measured at 1 meter away from the test chamber) | |
Gas flowmeter | H2S,SO2,NO2,CI2 | |
Standard
|
IEC60068-2-1:2007 Test A: Low temperature test method |
|
IEC60068-2-2:2007 Test B: High temperature test method
|
||
IEC60068-2-78:2007 Test Cab: Constant humidity and heat test
|
||
IEC60068-2-30:2005 Test Db: alternating humidity and heat test
|
||
GJB 150.3A-2009 High-temperature test
|
||
GJB 150.4A-2009 Low temperature test
|
||
GJB 150.9A-2009 Thermal-humidity test
|
||
IEC60068-2-60 Test Method KE: Man-made low concentration pollution gas corrosion test |
||
GB/T2423.51-2000 Environmental testing of electrical and electronic products Test KE: Flow mixed gas corrosion test
|
Enter Your Message