Detail Information |
|||
Name: | Thermal Shock Test Chamber | Usage: | Widely Used |
---|---|---|---|
Test Zones: | Two | Test Space Volume: | 50L 100L 200L |
Temp. Constancy: | ±0.3 ℃~±1.0 ℃ | Temp. Range: | -65℃ ~ +150 |
High Light: | 200 degree Thermal Shock Test Chamber,200L Thermal Shock Test Chamber,200L low temperature chamber |
Product Description
Features
★The Chamber is Fashion designed with modular construction |
★ Design with independent sensors to prevent specimens from damages caused by dewing, overheat, breezeless and smog |
★7'' colour touch screen with 32bit control system |
★ Intelligent and top-performance servo refrigerating control technology: energy saving and rapid heating/cooling rate. |
★ It can chose App mobility management | ★ The network video monitoring and data synchronization is optional |
★ The design of observation window with a reality visualization for real-time monitoring | ★ Automatic reminder of equipment maintenance plans and software of recording malfunction. |
★ Long defrosting cycles:over 700h's running before defrosting | ★ Unique operation mode: make testing area's temperature back to room temperature after tests are finished |
★ It can chose remote-assist service function and teaching CDs |
Specifications
Model | ET450S2 | ET4100S2 | ET4200S2 |
ET550S2 | ET5100S2 | ET5200S2 | |
ET650S2 | ET6100S2 | ET6200S2 | |
Test Space Volume (L) | 50 | 100 | 200 |
Test Zones | 2 | ||
Hot chamber Temp. Range (℃ ) | +50/+200 | ||
Cold chamber Temp. Range (℃) | -80/70 | -80/70 | -75/70 |
Temp. Constancy (℃ ) | ±0.3~±1.0 | ||
Temp. Homogeneity (℃) | ±0.5~±2.0 | ±0.5~±2.0 | ±1.0~±2.0 |
Recovery Time (min) | <1(on Air Outlet) | <5(on Air Outlet) | <5(on Air Outlet) |
Test Space Dimension (mm) | 400W*400D*310H | 500W*500D*400H | 600W*550D*600H |
External Dimension (mm) | 900W*2300D*2160H | 1000W*2400D*2250H | 1200W*2500D*2200H |
Temperature Range(℃) | -40/150 | -40/150 | -40/150 |
-55/150 | -55/150 | -55/150 | |
-65/150 | -65/150 | -65/150 | |
Cooling Methods | Air-Cooled Water-Cooled (IEC 60068-3-5) | ||
Power | AC380V ±10%, 50HZ, 3/N/PE | ||
Compliant with International Standards: | |||
GB/T2423.22 | Test Na BS 2011 | ||
MIL STD202F (Method 107G) | DIN40046, Test Na | ||
IEC 60068-2-14 | JESD22-A101-A |
Options | Standard Version |
☆ Independent sensors for specimen protection (NE60519-2.1993) | ☆ 2Stainless Steel shelves |
☆ Spare parts package | |
☆ E-management and cyber-software | |
☆ Video monitor system | |
☆ APP for mobility management | |
☆ 1 Entry port Φ100mm | |
☆ Nitrogen gas auxiliary device |