High Precision IEC Standard AC 380V Gas Test Chamber Stainless Steel
Contact Person : Jack He
Phone Number : +86-13842409825
WhatsApp : +8613842409825
Minimum Order Quantity : | 1 | Price : | USD |
---|---|---|---|
Packaging Details : | Well packed in strong wooden case suitable for all types of long distance shipment | Delivery Time : | 45 days |
Payment Terms : | L/C, T/T, Western Union | Supply Ability : | 35 per month |
Place of Origin: | China | Brand Name: | Envsin |
---|---|---|---|
Certification: | CE | Model Number: | EQF2330 |
Detail Information |
|||
Product Name: | Gas Test Chamber | Temperature Range: | 20℃~+45℃ |
---|---|---|---|
Temperature Uniformity: | ≤2.0℃ | Temperature Deviation: | ≤±2.0℃ |
Emperature Fluctuation: | ≤±0.5℃ | Temperature Rate: | ≥1℃/min |
Gas Concentration: | 5ppb~30ppm | Gas Flowmeter: | H2S,SO2,NO2,CI2 |
Standard: | GB/T2423 And IEC60068 | ||
High Light: | 25ppm cyclic corrosion chamber,H2S cyclic corrosion chamber,H2S gas test equipment |
Product Description
Test Equipment Gas Test Chamber With H2s Co2 So2 Corrosion Function
Technical Parameters (Product Model:EQF2330)
|
||
Temperature test
|
Temperature range:20℃~+45℃
|
Remark:
1. Test in accordance with GB/T2423 and IEC60068
under empty chamber condition (except indicated).
2. The test data of the water-cooled
test chamber are under the conditions that the water
temperature is less than 28, the water pressure is between 0.3Mpa and 0.6Mpa, and the
water pressure difference between inlet and outlet is more than 0.2Mpa.
|
Temperature uniformity:≤2.0℃ | ||
Temperature deviation:≤±2.0℃ | ||
Temperature fluctuation:≤±0.5℃ | ||
Temperature rate:≥1℃/min | ||
Temperature and humidity climatic test
|
Humidity temperature control range:20℃~+50℃ Humidity range:50%RH~85%RH |
|
Humidity uniformity:±5.0%RH | ||
Humidity deviation: +2.0%~3%RH(>75%RH)±5%R.H(≤75%RH) | ||
Humidity fluctuation:±5.0%RH | ||
Gas concentration | 5ppb~30ppm | |
The deviation of gas concentration in the chamber shall not exceed 10% of the set concentration,Concentration uniformity deviation of 10% | ||
The empty chamber operation request meets the IEC60068-2-60 standard | ||
Gas concentration measurement |
By calculating the volume ratio and then through the mass flowmeter measurement |
|
On load capacity |
500W,The temperature can be stable, the chamber body is not deformed
|
|
Noise
|
Working noise ≤70dB (measured at 1 meter away from the test chamber) | |
Wind speed
|
≤1.7m/s | |
Gas flowmeter | H2S,SO2,NO2,CI2 | |
Standard
|
GB/T 2423.1-2001 / (IEC60068-2-1:2007) Test A: Low temperature test method |
|
GB/T 2423.2-2001 / (IEC60068-2-2:2007) Test B: High temperature test method
|
||
GB/T 2423.3-2006 / (IEC60068-2-78:2007) Test Cab: Constant humidity and heat test |
||
GB/T 2423.4-2008 / (IEC60068-2-30:2005) Test Db: alternating humidity and heat test
|
||
GJB 150.3-1986 / GJB 150.3A-2009 High-temperature test
|
||
GJB 150.4-1986 / GJB 150.4A-2009 Low temperature test
|
||
GJB 150.9-1986 / GJB 150.9A-2009 Thermal-humidity test
|
||
IEC60068-2-60 Test Method KE: Man-made low concentration pollution gas corrosion test |
||
GB/T2423.51-2000 Environmental testing of electrical and electronic products Test KE: Flow mixed gas corrosion tes
|
GB/T 2423.1-2001 / (IEC60068-2-1:2007)
|
Test A: Low temperature test method
|
GB/T 2423.2-2001 / (IEC60068-2-2:2007)
|
Test B: High temperature test method
|
GB/T 2423.3-2006 / (IEC60068-2-78:2007)
|
Test Cab: Constant humidity and heat test
|
GB/T 2423.4-2008 / (IEC60068-2-30:2005)
|
Test Db: alternating humidity and heat test
|
GJB 150.3-1986 / GJB 150.3A-2009
|
High-temperature test
|
GJB 150.4-1986 / GJB 150.4A-2009
|
Low temperature test
|
GJB 150.9-1986 / GJB 150.9A-2009
|
Thermal-humidity test
|
IEC60068-2-60
|
Test Method KE: Man-made low concentration pollution gas corrosion test
|
GB/T2423.51-2000
|
Environmental testing of electrical and electronic products Test KE: Flow mixed gas corrosion test
|
Working principle Equipment design two sets of boxes, external temperature and humidity air conditioning cabinet + sample room. The air conditioning system has refrigeration system, heating system, humidification system, mixed gas inlet, exhaust gas discharge filter and other devices.
Before diluting corrosive gases are mixed, the air conditioning system creates the test temperature and humidity in the chamber outside the sample room. When the temperature and humidity are constant, the gas is input at the same time. The gas concentration is measured by calculating the volume ratio formula, and then the mass flowmeter is used for effective control, so that it reaches the specified range. In the test chamber, the gas is mixed evenly through the fan.
In the sample room, the air in the sample room is discharged through pumping, so that low pressure is formed in the sample room. Compared with the space outside the sample room in the test chamber, the wet air in the sample outdoor area is pumped into the sample room through the pipe. By recording the data, the flow rate of the air extracted from the sample chamber can be adjusted to obtain the specified number of gas volume changes per hour.