High Precision IEC Standard AC 380V Gas Test Chamber Stainless Steel
Contact Person : Jack He
Phone Number : +86-13842409825
WhatsApp : +8613842409825
Detail Information |
|||
Itme Name: | Gas Corrosion Test Chambe | Power: | AC220V±10%,50H |
---|---|---|---|
Model Number: | EQF2330 | Application: | Widely Use |
Temp. Deviation: | ≤±2.0℃ | Standard: | IEC60068-2-60 |
High Light: | NO2 corrosion test chamber,programmable Corrosion Test Chamber,programmable climate chamber humidity temperature |
Product Description
Mix Flow Gas corrosion Test Chamber with H2S SO2 NO2 CI2 GAS
Application
It is applied to pharmaceuticals, food, cosmetics, textiles, auto parts, packaging materials, building materials, electricity and the electrical products etc; The test Data result which is very useful for scientific research, product development and quality control sector to help them produce high quality anlysis report
Technical Parameters
Temperature test | Temperature range:20℃~+45℃ | Remark: 1. Test in accordance with GB/T2423 and IEC60068 under empty chamber condition (except indicated). 2. The test data of the water-cooled test chamber are under the conditions that the water temperature is less than 28, the water pressure is between 0.3Mpa and 0.6Mpa, and the water pressure difference between inlet and outlet is more than 0.2Mpa. |
Temperature uniformity:≤2.0℃ | ||
Temperature deviation:≤±2.0℃ | ||
Temperature fluctuation:≤±0.5℃ | ||
Temperature rate:≥1℃/min | ||
Temperature and humidity climatic test | Humidity temperature control range:20℃~+50℃ | |
Humidity range:50%RH~85%RH | ||
Humidity uniformity:±5.0%RH | ||
Humidity deviation: +2.0%~3%RH(>75%RH)±5%R.H(≤75%RH) | ||
Humidity fluctuation:±5.0%RH | ||
Gas concentration | 5ppb~30ppm | |
The deviation of gas concentration in the chamber shall not exceed 10% of the set concentration,Concentration uniformity deviation of 10% | ||
The empty chamber operation request meets the IEC60068-2-60 standard | ||
Gas concentration measurement | By calculating the volume ratio and then through the mass flowmeter measurement | |
On load capacity | 500W,The temperature can be stable, the chamber body is not deformed | |
Noise | Working noise ≤70dB (measured at 1 meter away from the test chamber) | |
Wind speed | ≤1.7m/s | |
Gas flowmeter | H2S,SO2,NO2,CI2 | |
Standard | GB/T 2423.1-2001 / (IEC60068-2-1:2007) Test A: Low temperature test method | |
GB/T 2423.2-2001 / (IEC60068-2-2:2007) Test B: High temperature test method | ||
GB/T 2423.3-2006 / (IEC60068-2-78:2007) Test Cab: Constant humidity and heat test | ||
GB/T 2423.4-2008 / (IEC60068-2-30:2005) Test Db: alternating humidity and heat test | ||
GJB 150.3-1986 / GJB 150.3A-2009 High-temperature test | ||
GJB 150.4-1986 / GJB 150.4A-2009 Low temperature test | ||
GJB 150.9-1986 / GJB 150.9A-2009 Thermal-humidity test | ||
IEC60068-2-60 Test Method KE: Man-made low concentration pollution gas corrosion test | ||
GB/T2423.51-2000 Environmental testing of electrical and electronic products Test KE: Flow mixed gas corrosion test |
Enter Your Message