GJB Standard 3.3m3 Gas Test Chamber , Drive In Test Chamber Accelerated

Minimum Order Quantity : 1 Price : USD
Packaging Details : Well packed in strong wooden case suitable for all types of long distance shipment Delivery Time : 45 days
Payment Terms : L/C, T/T, Western Union Supply Ability : 35 per month
Place of Origin: China Brand Name: Envsin
Certification: CE Model Number: EQF2330

Detail Information

Product Name: Drive-in Gas Test Chamber The Test Volume: 3.3 M3
Outer Dimensions: 1200mm*1200mm*2300mm (W *D * H) Exterior Dimensions: 1500mm*2400MM*2600mm (W *D * H)
Gas Flowmeter: H2S,SO2,NO2,CI2 Gas Concentration: 5ppb~30ppm
Standard: GB,GJB,IEC
High Light:

GJB Gas Test Chamber

,

3.3m3 Gas Test Chamber

,

GJB drive in test chamber

Product Description

H2S,SO2,NO2,CI2 Drive-in Gas Test Chamber Accelerated Drive-in Test Chamber

 

Gas corrosion system:

Working principle Equipment design two sets of boxes, external temperature and humidity air conditioning cabinet + sample room. The air conditioning system has refrigeration system,heating system, humidification system, mixed gas inlet, exhaust gas discharge filter and other devices.

 

Before diluting corrosive gases are mixed, the air conditioning system creates the test temperature and humidity in the chamber outside the sample room. When the temperature and humidity are constant, the gas is input at the same time. The gas concentration is measured by calculating the volume ratio formula, and then the mass flowmeter is used for effective control, so that it reaches the specified range.In the test chamber, the gas is mixed evenly through the fan.

 

In the sample room, the air in the sample room is discharged through pumping, so that low pressure is formed in the sample room. Compared with the space outside the sample room in the test chamber, the wet air in the sample outdoor area is pumped into the sample room through the pipe. By recording the data, the flow rate of the air extracted from the sample chamber can be adjusted to obtain the specified number of gas volume changes per hour.

 

GJB Standard 3.3m3 Gas Test Chamber , Drive In Test Chamber Accelerated 0

Load Condition:
  • The total mass of the load placed per cubic meter of studio volume shall not exceed 80KG
  • The load physical volume is not greater than 2/5 of the studio volume
  • At any section perpendicular to the wind direction of the inner circulation, the total area of the sample load should not be greater than 1/3 of the cross-sectional area of the studio in this direction. Oversized sample load will affect the air balance and smooth of the chamber
 
Specification:
Drive-in Gas Test Chamber Technical Parameters (Product Model:EQF2330)
Temperature test
Temperature range:20℃~+45℃
Remark:
1. Test in accordance with GB/T2423 and IEC60068 under empty chamber 
condition (except indicated).
 
2. The test data of the water-cooled test chamber are under the conditions that the water temperature is less than
28, the water pressure is between 0.3Mpa and 0.6Mpa, and the water pressure difference between inlet and outlet is more than 0.2Mpa.
Temperature uniformity:≤2.0℃
Temperature deviation:≤±2.0℃
Temperature fluctuation:≤±0.5℃
Temperature rate:≥1℃/min
Temperature and humidity climatic test

Humidity temperature control range:20℃~+50℃

Humidity range:50%RH~85%RH

Humidity uniformity:±5.0%RH
Humidity deviation: +2.0%~3%RH(>75%RH)±5%R.H(≤75%RH)
Humidity fluctuation:±5.0%RH

 

Gas concentration

5ppb~30ppm
The deviation of gas concentration in the chamber shall not exceed 10% of the set concentration,Concentration uniformity deviation of 10%
The empty chamber operation request meets the IEC60068-2-60 standard

Gas concentration measurement

By calculating the volume ratio and then through the mass flowmeter measurement

On load capacity

500W,The temperature can be stable, the chamber body is not deformed
Noise
Working noise ≤70dB (measured at 1 meter away from the test chamber)
Wind speed
≤1.7m/s
Gas flowmeter H2S,SO2,NO2,CI2

 

Standard:
1. GB/T 2423.1-2001 / (IEC60068-2-1:2007)
  • Test A: Low temperature test method
2. GB/T 2423.2-2001 / (IEC60068-2-2:2007)
  • Test B: High temperature
3. GB/T 2423.3-2006 / (IEC60068-2-78:2007)
  • Test Cab: Constant humidity and heat test
4. GB/T 2423.4-2008 / (IEC60068-2-30:2005)
  • Test Db: alternating humidity and heat test
5. GJB 150.3-1986 / GJB 150.3A-2009
  • High-temperature test
6. GJB 150.4-1986 / GJB 150.4A-2009
  • Low temperature test
7. GJB 150.9-1986 / GJB 150.9A-2009
  • Thermal-humidity test
8. IEC60068-2-60
  • Test Method KE: Man-made low concentration pollution gas corrosion test
9. GB/T2423.51-2000
  • Environmental testing of electrical and electronic products Test KE: Flow mixed gas corrosion test