JIS H8502 Temperature And Humidity Test Chamber With ISO Certification

Minimum Order Quantity : 1 Price : $8000 >=1 Set
Delivery Time : 35 days Payment Terms : L/C, T/T, Western Union, D/P
Supply Ability : 25 per month
Place of Origin: China Brand Name: Envsin
Certification: CE and ISO Model Number: EC

Detail Information

Product Name: Temperature And Humidity Test Chamber Power: Electronic
Test Space Dimension(mm): 800W*800D*950H External Dimension(mm): 1090W*1960D*1995H
Usage: Universal Testing Machine,Process Testing Machine,Temperature Humidity Test Chamber For Resisting Heat,Textile Testing Instrument,Low Temp Test Standard: IEC60068-2-1,JIS H8502,IEC 68-2-11
Warranty: 12 Months Color: White And Blue
High Light:

JIS H8502 Temperature And Humidity Test Chamber

,

ISO Temperature And Humidity Test Chamber

,

JIS H8502 environmental temperature chamber

Product Description

Customized Temperature and Humidity with Chamber With CE certification

The Chamber Provides conditions of temperature from -42 to +180 degree and of humidity from 10% to 98%.

 
Products Features:
•Fashionable design of modular construction
•4 load power outlets for specimens with programmable control for protection
•Special air circulation system inside ensures testing accuracy.(Patented)
•Optional network video monitoring and data synchronization
•Automatic water supply with ultra purifier devices(optional);water short agree minder function

•Environment-friendly refrigerating control technology energy saving and rapid heating/cooling rate

•Automatic reminder of equipment maintenance plans and software of recording malfunction
•Optional APP mobility management
•Design with independent sensors to prevent specimens from damages caused by drew,overheat,breeze less and smog.
•Special anti-condensation structures to avoid misjudgment and improve testing accuracy during climate testing.(Patented)
•Strong control abilities of extreme-low humidity range 20℃/10% R.H..
• Unique operation mode: make testing area's temperature back to room temperature after tests are finished
•Optional remote-assist service function and teaching CDs

 

Specifications:

Model:

Temperature Humidity

Chamber

 

EC4018

 

EC7018

 

EC4034

 

EC7034

 

EC4060

 

EC7060

 

EC4100

 

EC7100

 

EC4150

 

EC7150

Test Space Volume(L) 190 335 600 990 1540
Temperature Test Parameters:
Temp. Range (℃) -42/+180 -72/+180 -42/+180 -72/+180 -45/+180 -72/+180 -45/+180 -73/+180 -42/+180 -73/+180

Temp. Constancy (℃)

±0.1-±0.5

Temp. Homogeneity (℃)

±0.5-±2.0

Heating Rate(℃/min) 4.0 4.0 3.2 3.0 4.0 4.0 4.0 4.0 3.5 3.5
Cooling Rate (℃/min) 4.0 3.0 4.0 3.0 3.0 2.5 3.0 2.5 2.5 2.3

Temp. Max. Thermal

Compensation (W)

2800 1500 2800 1500 1500 2500 4500 3000 4200 3000
Climate Test Parameters:
Dewpoint Temp.Range (℃)

+4(-3)-+94

Humid. Range (%RH) 10-98
Humid.Constancy (%RH) ±1.0-±3
Temp. Constancy (℃) ±0.1-±0.3
Temp. Homogeneity (℃) ±0.5-±2.0
Temp and Humid Max.Thermal Compensation (W)

 

400

 

400

 

400

 

400

 

500

 

500

 

500

 

500

 

500

 

500

Power AC380V±10%,50HZ,3/N/PE

Optional Accessories:

Standard Version:

Independent sensors for specimen protection(NE60519-2.1993)

3 Power outlets for specimens

1 Entry port Φ100mm

Left and right entry ports Φ50mm

Drier filter for compressing air

Silicon Stoppers for entry ports

Automatic water supply device

2 Stainless steel shelves

Nitrogen gas auxiliary device

1 Water tank with 20L

Water-Cooled unit

1 Water filter

Spare parts package

 

E-management and cyber software

 
Video monitor system  
APP for mobility management  

 

Load condition requirements:

The total mass of the load placed per cubic meter of studio volume shall not exceed 80KG

The load of each layer of test material placement rack shall not exceed 20KG

The load physical volume is not greater than 2/5 of the studio volume

At any section perpendicular to the wind direction of the inner circulation, the total area of the sample load

should not be greater than 1/3 of the cross-sectional area of the studio in this direction. Oversized sample

load will affect the air balance and smooth of the studio

 

Temperature Humidity Chamber Standards:

 

IEC60068-2 temperature and humidity test method 8,

MIL-STD-202G-103B humidity test

 

Structure of the way:

Integral, (test chamber door direction is in front) front for the studio, refrigeration unit, after the electric

control cabinet and electric control device, the main control interface is located in front of the test chamber

door, expansion control panel is located in the right back of the test chamber. The door is open in the width

direction. At the back of the studio, there are circulating air duct system and air conditioning system: centrifugal

fan blade, air guide device, heater, humidifier, refrigeration heat exchanger, temperature and humidity sensor.

 

Quality Control

EC4060 New Model Customized Temperature Humidity chamber

EC4060 New Model Customized Temperature Humidity chamber

About Us

EC4060 New Model Customized Temperature Humidity chamber

Cooperation partner

EC4060 New Model Customized Temperature Humidity chamber

Customer

EC4060 New Model Customized Temperature Humidity chamber

Exhibition hall

EC4060 New Model Customized Temperature Humidity chamber

EC4060 New Model Customized Temperature Humidity chamber

EC4060 New Model Customized Temperature Humidity chamber

EC4060 New Model Customized Temperature Humidity chamber

You Might Be Into These
Get in touch with us

Enter Your Message

envsin61@envsin.com
+8613842409825
he
+86-13842409825
+86-13842409825