Walk-in Vehicle Temperature Humidity Chamber

Walk-in Vehicle Temperature Humidity Chamber

2023-06-26

latest company case about Walk-in Vehicle Temperature Humidity Chamber  0latest company case about Walk-in Vehicle Temperature Humidity Chamber  1

Model No.: ETCZ686/6090

1.Temperature Humidity Testing Specifications:

Temperature Range:-70°C to 90°C

Humidity range:20%~98%

 

2. Chamber Volume

I. Test room: 7000mm × 14000mm × (8000/4500) mm (Length × Width × Height)

• The depth of 14000mm can be divided into three parts: 10000mm + 4000mm (middle part with partition plates, each section is divided separately).

• A. Approximately 7000mm × 10000mm × 8000mm (Width × Depth × Height) (560m³)

• B. Approximately 7000mm × 4000mm × 4500mm (Width × Depth × Height) (126m³)

II. External dimension: 16200x15700x8850mm(W*D*H) Includes the size of the transition chamber, excluding the protruding parts.

III. Transition chamber size: 1500x1500x2200mm Door opening size: 900x1900mm (WH) Observation window: 400x500mm (WH) Monitoring room independent construction: 3000x4000x2500mm (WDH)

IV. Warehouse A: Main door: 6600x5000mm (W*H), single door, electric side sliding door One observation window on each side of the main door, approximately 400x500mm

V. Warehouse B: Main door: Sliding type with auxiliary power, operable by one person, good sealing, size: 4000x4500mm (W*H), one observation window on each side of the main door: 400x500mm

VI. Partitions between warehouses: Double-layer partitions, partition doors with two reserved test holes, hole diameter 150mm, partition door opening size: 6600x4500mm

3.Testing Standard

I. Empty Load Temperature and Humidity Measurement

• Temperature range: -60℃ ~ 90℃ • Humidity range: 25% RH ~ 98% RH

• Temperature change rate: ≥1℃/min (-55℃ ~ 70℃)

II. Loaded Temperature Change Rate Measurement Total vehicle weight 60T, constant temperature heat load 150KW conditions:

A. Heating rate: ≥1℃/min (-55℃ ~ 70℃, average value)

B. Cooling rate: ≥0.5℃/min (-55℃ ~ 70℃, average value)

Total vehicle weight 45T, heating and cooling heat load 50KW conditions:

C. Heating rate: 1℃/min (-55℃ ~ 70℃, average value)

D. Cooling rate: 0.5℃/min (-55℃ ~ 70℃, average value)

Total vehicle weight 15T, heating and cooling heat load 50KW conditions:

E. Heating rate: 1℃/min (-55℃ ~ 70℃, average value)

F. Cooling rate: 0.5℃/min (-55℃ ~ 70℃, average value)

banner
Solutions Details
Created with Pixso. Home Created with Pixso. Solutions Created with Pixso.

Walk-in Vehicle Temperature Humidity Chamber

Walk-in Vehicle Temperature Humidity Chamber

2023-06-26

latest company case about Walk-in Vehicle Temperature Humidity Chamber  0latest company case about Walk-in Vehicle Temperature Humidity Chamber  1

Model No.: ETCZ686/6090

1.Temperature Humidity Testing Specifications:

Temperature Range:-70°C to 90°C

Humidity range:20%~98%

 

2. Chamber Volume

I. Test room: 7000mm × 14000mm × (8000/4500) mm (Length × Width × Height)

• The depth of 14000mm can be divided into three parts: 10000mm + 4000mm (middle part with partition plates, each section is divided separately).

• A. Approximately 7000mm × 10000mm × 8000mm (Width × Depth × Height) (560m³)

• B. Approximately 7000mm × 4000mm × 4500mm (Width × Depth × Height) (126m³)

II. External dimension: 16200x15700x8850mm(W*D*H) Includes the size of the transition chamber, excluding the protruding parts.

III. Transition chamber size: 1500x1500x2200mm Door opening size: 900x1900mm (WH) Observation window: 400x500mm (WH) Monitoring room independent construction: 3000x4000x2500mm (WDH)

IV. Warehouse A: Main door: 6600x5000mm (W*H), single door, electric side sliding door One observation window on each side of the main door, approximately 400x500mm

V. Warehouse B: Main door: Sliding type with auxiliary power, operable by one person, good sealing, size: 4000x4500mm (W*H), one observation window on each side of the main door: 400x500mm

VI. Partitions between warehouses: Double-layer partitions, partition doors with two reserved test holes, hole diameter 150mm, partition door opening size: 6600x4500mm

3.Testing Standard

I. Empty Load Temperature and Humidity Measurement

• Temperature range: -60℃ ~ 90℃ • Humidity range: 25% RH ~ 98% RH

• Temperature change rate: ≥1℃/min (-55℃ ~ 70℃)

II. Loaded Temperature Change Rate Measurement Total vehicle weight 60T, constant temperature heat load 150KW conditions:

A. Heating rate: ≥1℃/min (-55℃ ~ 70℃, average value)

B. Cooling rate: ≥0.5℃/min (-55℃ ~ 70℃, average value)

Total vehicle weight 45T, heating and cooling heat load 50KW conditions:

C. Heating rate: 1℃/min (-55℃ ~ 70℃, average value)

D. Cooling rate: 0.5℃/min (-55℃ ~ 70℃, average value)

Total vehicle weight 15T, heating and cooling heat load 50KW conditions:

E. Heating rate: 1℃/min (-55℃ ~ 70℃, average value)

F. Cooling rate: 0.5℃/min (-55℃ ~ 70℃, average value)