Contact Us

Contact Person : Jack He

Phone Number : +86-13842409825

WhatsApp : +8613842409825

Free call

28m3 NE60519-2.1993 Walk In Environmental Test Chamber APP Mobility Management

Minimum Order Quantity : 1 Price : To Be Negotiated
Packaging Details : Wooden packing Delivery Time : 30-35 business days after received the payment
Payment Terms : L/C, T/T, Western Union Supply Ability : 25 per month
Place of Origin: China Brand Name: Envsin
Certification: CE and ISO Model Number: ECZ12W5

Detail Information

Product Name: Walk In Chamber Keyword: Walk In Chamber
Color: White/Blue Standard: NE60519-2.1993
Warranty: 12 Months Power: AC 380V±10%, 50HZ , 3/N/PE
High Light:

28m3 Walk In Environmental Test Chamber

,

NE60519-2.1993 Walk In Environmental Test Chamber

,

28m3 thermal shock chamber

Product Description

Optional APP Mobility Management Walk in Chamber Environmental Walk in Chamber

 

The Walk in Chamber is suitable for large size or a large number of machine products, parts, materials for high temperature, low temperature, high low temperature cycle test, and humid heat test. It is mainly used to simulate the product under the combined conditions of climate temperature and humidity or under the changing conditions of ambient temperature and humidity to detect whether the adaptation ability and characteristics of the product change.

 

Standard:

      1. Test methods for environmental test equipment for electrical and electronic products 

      • Temperature test equipment

 

      2. Test methods for environmental test equipment for electrical and electronic products

      • Humidity and heat test equipment

 

      3. JJF1101-2003 environmental test equipment temperature, humidity calibration specification

 

Structure:
  • (Split type or integral type)Split structure, the main body for the studio, split for the refrigeration unit cabin;Main studio: with the test chamber door, the main control interface and distribution system are located on the left side of the chamber; The main studio includes circulating air duct system and air conditioning system: centrifugal fan blade,air guide device, heater, humidifier, refrigeration heat exchanger, temperature and humidity sensor.
  • Refrigerating unit cabin: separated from the main studio, the partition wall is placed in a separate space, and the refrigeration unit cabin and the main studio are connected by pipes and cables.Integral structure, test chamber (studio), refrigeration unit, electronic control device and other structural components through the modular assembly of the whole installation.

28m3 NE60519-2.1993 Walk In Environmental Test Chamber APP Mobility Management 0

Features:
• Globally advanced modular design.
• Combined seamless welding technology for permanent aniti-deformation building.
• Special sensors equipped to prevent specimens from damages caused by overheat,
breezeless and no-exhaust when power-off.
• Optional ultrasonic humidification system for high thermal load testing.(Patented)
• 7' colour touch screen display and 32 bit control system; interface Ethernet/USB.
• Optional APP mobility management.
• 4 load power outlets for specimens with programmable control for protection.
• Special air circulation system inside ensures testing accuracy .(Patented)
• Optional network video monitoring and data synchronization.
• Special anti condensation function to protect specimens during climate testing.
• Automatic water supply with ultrapure filter devices (optional) ; water shortage reminder function.
• Environment-friendly refrigerating control technology: energy saving and rapid heating/cooling rate.
• Unique design: no-need defrosting during long period operation in low temperature.
• Unique operation mode: make testing space's temperature back to room temperature after tests are finished.
• Automatic reminder of equipment maintenance plans and software of recording malfunction.
• Optional remote-assist service function and teaching CDs.
 
Specifications:
Temperature Chambers ETZ8/4010 ETZ12/4010 ETZ17/4010 ETZ28/4010
Climate Chambers ECZ8/010 ECZ12/010 ECZ17/010 ECZ28/010

Temperature Climate Cycling Chambers

ETCZ8/4010

ETCZ12/4010

ETCZ17/4010

ETCZ28/4010

Test Space Volume (m³) 8 12 17 28
Test Space Dimension (mm) 2000W*2000D*2056H 2000W*2000D*3040H 2250W×2500D×3032H 2250W*2500D*5000H
External Dimension (mm) 2240W*2240D*3800H 2240W*2240D*4780H 2490W*2740D*4900H 2490W*2740D*6860H
Floor Load (N/m³)

30000

ETZ Series: -60,-40 / +80,+100,+150, +180 optional

Temp. Range (℃) (NoLoad) ECZ Series: 0 / +80,+100 optional
Humid. Range (%RH) ETCZ Series: -60,-40 / +80,+100,+150 optional

Dewpoint Temp. Range (℃)

15~95 (ETZ,ETCZ Series)

+4~+59 / +4~+95

Heating /Cooling Rate (IEC60068-3-5)

Level 1 (K/min) 4.5 3.7 2.7 1.7
Level 2 (K/min) 5.5 4.5 3.2 2.0
Temp. Constancy (K) ±0.1~±0.5 (IEC60068-3-5)
Temp.Homogeneity (K) ±0.5~±3.0 (IEC60068-3-5)
Humid. Constancy Entry (%RH) ±1.0~±5.0 (IEC60068-3-5) (ECZ, ETCZ Series)
Door Dimension Power(mm) 900W×1900H(Single door) , 2000W*2000H (Double door)
Power AC 380V±10%, 50HZ , 3/N/PE

Options Accessories

Standard Version

Independent sensors for specimen protection (NE60519-2.1993)

1 Entry port Φ100mm

1 Entry port Φ50mm

1 Silicon stopper for entry port

Drier filter for compressingair

Automatic water supply

Ultrasonic Humidifier

1 Water tank with 20L

Nitrogen gas auxiliary device

1 Water filter

Water-Cooled unit

 

Spare parts package

 

E-management and cyber-software

 

Video monitor system

 

APP for mobility management

 

You Might Be Into These
Get in touch with us

Enter Your Message

envsin63@envsin.com
+8613842409825
he
+86-13842409825
+86-13842409825