Envsin 500L Hydrostatic Pressure Chamber With Temperature Humidity Control

Minimum Order Quantity : 1 set Price : $5000 >=1 Set
Delivery Time : 35 work days Payment Terms : L/C, D/A, D/P, T/T, Western Union
Supply Ability : 30 sets per month
Place of Origin: Guangdong Brand Name: Envsin
Certification: ISO CE Model Number: ECQ

Detail Information

Test Volume: 250L,500L,2000L And Other Customized Temperature Range: -70℃~ 150℃
Heating And Cooling Rate: 1℃/min,3℃/min,5℃/min(Adjustable) Air Pressure Range: Normal Pressure~0.5kPa
Depressurization Time: <= 45 Min (normal Pressure~1 KPa) Pressure Precision: ±2 KPa Target Value(normal Pressure~40kPa)
Warranty: 12 Months
High Light:

Envsin hydrostatic pressure chamber

,

500L hydrostatic pressure chamber

,

500L lab humidity chamber

Product Description

 

Altitude Chambers With Temperature And Humidity Controls
 
This test chamber is suitable for simulating environmental tests of high temperature, low temperature,damp heat, low air pressure single climate factor or multiple climatic factors for the whole machine,components and materials.
 
Our Service

• Be able to provide a complete testing solution

• Preferential supplier of Apple ,Cisco and Huawei in China

• Perfect systematic pre-sale and after-sale technical support
Envsin 500L Hydrostatic Pressure Chamber With Temperature Humidity Control 0
Envsin 500L Hydrostatic Pressure Chamber With Temperature Humidity Control 1
Features 
• High performance water ring vacuum pump controls low pressure.

modular design .
 
• 32 bit control system; interface
Ethernet/USB.

 
• Built-in radiation shield ensures temperature homogeneity in low air pressure.
 
• Intelligent and independent protection design for overload, overheat,power supply abnormity, overvoltage, component malfunction monitoring.
 
• Customer-friendly software functions: intelligent power-recovery restoration,auto-connect on memory and auto-reset restart.
 

• Customer-friendly design: observation window in testing space

 

• Automatic water supply with ultrapure filter devices
water shortage reminder function.

 

 

• Intelligent and high-performance servo refrigerating 
control technology: heating/cooling rate.
 
• Unique operation mode: make testing area's temperature back to room temperature after tests are finished.
 
• Automatic reminder of equipment maintenance plans and software of recording malfunction.

 

Application
Envsin 500L Hydrostatic Pressure Chamber With Temperature Humidity Control 2
Product Paramenters
Temp Chambers
ETQ7025
ETQ7050
ETQ7100
ETQ7200
Climate Chambers
ECQ7025
ECQ7050
ECQ7100
ECQ7200
Test Space Volume (L)
250
500
1000
2000
Temp. Test Parameters:
Temp. Range (℃)
-70~+150
Temp. Constancy (℃)
±0.1-±0.8 (Atmospheric Pressure No Load)
Temp. Homogeneity(℃)
±0.5-±2.0 (Atmospheric Pressure No Load)
Temp. Accuracy (℃)
±2.0 (Atmospheric Pressure No Load)
Heating Up Time (min) (+ 20℃ to ~150℃)
 
60
 
60
 
50
 
60
Cooling Down Time (min) (+ 20℃ to~60℃)
 
90
 
80
 
60
 
80
Pressure Range (Kpa)
Atmospheric Pressure ~1.0 Atmospheric Pressure ~0.5
Pressure Accuracy (Kpa)
±2 (Atmospheric Pressure ~40KPa); ±5%(40KPa~4KPa); ±0.1(4KPa~1KPa)
Pressure Release Time (min)
 
45(Atmospheric Pressure→1KPa)
Rapid Release of Pressure Function (optional)
 
Pressure Release Range: 75.2KPa → 18.8KPa; Pressure Release Time: 15sec
Climate Test Parameters for ECQ series:
Temp. Range (℃)
+10~+95
Temp.Constancy (℃)
±0.1~±0.8 (Atmospheric Pressure No Load)
Temp. Homogeneity (℃)
±0.1~±2.0 (Atmospheric Pressure No Load)
Humid. Range (%RH)
(10) 20-98 (Atmospheric Pressure No Load)
Humid. Constancy (%RH)
±1-±3 (Atmospheric Pressure No Load)
Test Space Dimension (mm)
 
600W×600D×700H
 
800W×700D×900H
 
1000W×1000D×1000H
 
1400W×1200D×1200H
External Dimension (mm)
1000W×1800D×1880H
1500W×2750D×1900H
1400W×3250D×2000H
1810W×3710D×2310H
Power
AC380V±10%, 50Hz, 3/N/PE
Cooling Methods
Water-Cooled
Options Accessories
Iindependent sensors for specimen protection (NE60519-2.1993)
• 1 Entry port Φ50mm
• Nitrogen gas auxiliary device
• Spare parts package
• E-management and cyber-software
• Video monitor system
• APP for mobility management
Quality Control
Envsin 500L Hydrostatic Pressure Chamber With Temperature Humidity Control 3
Envsin 500L Hydrostatic Pressure Chamber With Temperature Humidity Control 4
Envsin 500L Hydrostatic Pressure Chamber With Temperature Humidity Control 5
Envsin 500L Hydrostatic Pressure Chamber With Temperature Humidity Control 6
Envsin 500L Hydrostatic Pressure Chamber With Temperature Humidity Control 7
Envsin 500L Hydrostatic Pressure Chamber With Temperature Humidity Control 8
Envsin 500L Hydrostatic Pressure Chamber With Temperature Humidity Control 9
Envsin 500L Hydrostatic Pressure Chamber With Temperature Humidity Control 10
Envsin 500L Hydrostatic Pressure Chamber With Temperature Humidity Control 11
Envsin 500L Hydrostatic Pressure Chamber With Temperature Humidity Control 12
Envsin 500L Hydrostatic Pressure Chamber With Temperature Humidity Control 13
Envsin 500L Hydrostatic Pressure Chamber With Temperature Humidity Control 14
Standard Version
1 Set testing electrode
• Electronic temperature and humidity sensors
 

You Might Be Into These
Get in touch with us

Enter Your Message

envsin61@envsin.com
+8613842409825
he
+86-13842409825
+86-13842409825