Brand Name: | Envsin |
Model Number: | ETQ |
MOQ: | 1 |
Price: | $15,000.00 >=1 Sets |
Payment Terms: | Western Union, T/T |
☆ High-performance water ring vacuum pump controls low pressure | ☆ Optional remote-assist service function and teaching CDs |
☆ Optonal APP mobility management | ☆ Optional network video monitoring and data synchronization |
☆ Fashionable desig of modular construction | ☆ Automatic water supply with Ultrapure filter devices water shortage reminder function |
☆ 7" colour touch screen display and 32 bit control system; interfce Ethernet/USB | ☆ Customer-friendly software: observation window in testing space with a reality visualization for real-time monitoring |
☆ Built-in radiation shield ensures temperature homogeneity in low air pressure | ☆ Intelligent and high-performance servo refrigerating control technology: energy saving and rapid heating/cooling rate |
☆ Customer-friendly software functions: intelligent power-recovery restoration, auto-connect on memory and auto-reset restart | ☆ Unique operation mode: make testing area's temperature back ro room temperature after tests are finished |
☆ Intelligent and independent protection design for overload, overheat, powersupply abnormity, overvoltage, component malfunction monitoring | ☆ Automatic reminder of equipment maintenance plans and software of recording malfunction |
Specifications
Tempreature Chambers | ETQ7025 | ETQ7050 | ETQ7100 | ETQ7200 |
Climate Chambers | ECQ7025 | ECQ7050 | ECQ7100 | ECQ7200 |
Test Space Volume (L) | 250 | 500 | 1000 | 2000 |
Temp. Test Parameters: | ||||
Temp. Range ( ℃ ) | -70/+150 | |||
Temp.Constancy (℃) | ±1.0 ~ ±0.8 (Atmospheric Pressure No Load) | |||
Temp. Homogeneity (℃) | ±0.5 ~ ±2.0 (Atmospheric Pressure No Load) | |||
Temp. Accuracy (℃) | ±2.0 (Atmospheric Pressure No Load) | |||
Heat Up Time (min) (+20℃ to~150℃) | 60 | 60 | 50 | 60 |
Cooling Down Time (min) (+20℃ to~60℃) | 90 | 80 | 60 | 80 |
Pressure Range (Kpa) | Atmospheric Pressure~ 1.0 Atmospheric Pressure ~ 0.5 | |||
Pressure Accuracy (Kpa) | ±2.0 (Atmospheric Pressure~ 40Kpa);±5%(40KPa~4KPa);±0.1(4KPa~1KPa) | |||
Pressure Release Time (min) | 45(Atmospheric Pressure→1KPa) | |||
Rapid Release of Pressure Function (Optional) | Pressure Release Range:75.2KPa →18.8KPa; Pressure Release Time:15sec | |||
Climate Test Parameters for ECQ series: | ||||
Temp. Range (℃) | +10 ~ +95 | |||
Temp. Constancy (℃) | ±1.0 ~ ±0.8 (Atmospheric Pressure No Load) | |||
Temp. Homogeneity (℃) | ±1.0 ~ ±2.0 (Atmospheric Pressure No Load) | |||
Humid. Range (%RH) | (10) 20 ~ 98 (Atmospheric Pressure No Load) | |||
Humid. Constancy (%RH) | ±1.0 - ±3.0 (Atmospheric Pressure No Load) | |||
Test Space Dimension (mm) | 600W×600D×700H | 800W*700D*900H | 1000W×1000D×1000H | 1400W*1200D*1200H |
External Dimension (mm) | 1000W×1800D×1800H | 1500W*2750D*1900H | 1400W×3250D×2000H | 1810W*3710D*2310H |
Power | AC380V±10%,50HZ,3/N/PE | |||
Cooling Methods | Water-Cooled |
Operation System Display
Application