Send Message

products details

Created with Pixso. Home Created with Pixso. Products Created with Pixso.
High Altitude Test Chamber
Created with Pixso.

-70 Degree 1000L Programmable Altitude Test Chamber for Electronics Reliability Testing

-70 Degree 1000L Programmable Altitude Test Chamber for Electronics Reliability Testing

Brand Name: Envsin
Model Number: ETQ7100
MOQ: 1
Price: To Be Negotiated
Payment Terms: L/C, T/T, Western Union
Supply Ability: 25 per month
Detail Information
Place of Origin:
China
Certification:
CE and ISO
Product Name:
High Altitude Test Chamber
Test Space Volume(L):
1000L
Test Space Dimension:
1000mm*1000mm*1000mm
External Dimension:
1400mm*3250mm*2000mm
Temperature Range:
-70~150 Degree
Temp. Constancy(℃):
±0.1-±0.8(Atmospheric Pressure No Load)
Temp. Homogeneity (℃):
±0.5-±2.0(Atmospheric Pressure No Load)
Temp. Accuracy(℃):
±2.0 (Atmospheric Pressure No Load)
Usage:
High Altitude Test
Pressure Range:
Atmospheric Pressure ~1.0 Atmospheric Pressure ~0.5(Kpa)
Inner Material:
SUS#304 Stainless Steel
Compressor:
Tecumseh-french
Controller:
Independent R&D Software
Warranty:
1 Year
Packaging Details:
Wooden packing
Supply Ability:
25 per month
Highlight:

-70 Degree High Altitude Test Chamber

,

High Altitude Test Chamber

,

1000L lab humidity chamber

Product Description

1000L Vacuum Pump Controls High Altitude Test Chamber For Sale

 

Application:

This high altitude test chamber is suitable for simulating environmental tests of high temperature,low temperature,damp heat,low air pressure single climate factor or multiple climatic factors for the whole machine,components and materials.

 

Specifications:
Temperature Chambers ETQ7025 ETQ7050 ETQ7100 ETQ7200
Climate Chambers ECQ7025 ECQ7050 ECQ7100 ECQ7200
Test Space Volume (L) 250 500 1000 2000
Temp. Test Parameters:
Temp. Range (℃) -70~+150
Temp. Constancy (℃) ±0.1-±0.8 (Atmospheric Pressure No Load)
Temp. Homogeneity(℃) ±0.5-±2.0 (Atmospheric Pressure No Load)
Temp. Accuracy (℃) ±2.0 (Atmospheric Pressure No Load)
Heat Up Time (min) (+ 20℃ to ~150℃)

 

60

 

60

 

50

 

60

Cooling Down Time (min) (+ 20℃ to~60℃)

 

90

 

80

 

60

 

80

Pressure Range (Kpa) Atmospheric Pressure ~1.0 Atmospheric Pressure ~0.5
Pressure Accuracy (Kpa) ±2 (Atmospheric Pressure ~40KPa); ±5%(40KPa~4KPa); ±0.1(4KPa~1KPa)
Pressure Release Time (min)

45(Atmospheric Pressure→1KPa)

Rapid Release of Pressure Function (optional)

Pressure Release Range: 75.2KPa → 18.8KPa; Pressure Release Time: 15sec

Climate Test Parameters for ECQ series:
Temp. Range (℃) +10~+95
Temp.Constancy (℃)

±0.1~±0.8 (Atmospheric Pressure No Load)

Temp. Homogeneity (℃)

±0.1~±2.0 (Atmospheric Pressure No Load)

Humid. Range (%RH) (10) 20-98 (Atmospheric Pressure No Load)
Humid. Constancy (%RH)

±1-±3 (Atmospheric Pressure No Load)

Test Space Dimension (mm)

600*600*700

800*700*900

1000*1000*1000

1400W*1200D*1200H

External Dimension (mm) 1000*1800*1880 1500*2750*1900 1400*3250×2000 1810W*3710D*2310H
Power AC380V±10%, 50HZ, 3/N/PE
Cooling Methods Water-Cooled

High Altitude Test chamber Options Accessories

High Altitude Test chamber Standard Version

• Iindependent sensors for specimen protection (NE60519-2.1993)

•1 Set testing electrode

•Nitrogen gas auxiliary device

•Electronic temperature and humidity sensors

•Spare parts package

 

•E-management and cyber-software

 

•Video monitor system

 

•APP for mobility management

 

•Rapid release of pressure device

 

•Rapid recovered pressure device

 

 

-70 Degree 1000L Programmable Altitude Test Chamber for Electronics Reliability Testing 0