Brand Name: | Envsin |
Model Number: | EC |
MOQ: | 1 set |
Price: | $8000 >=1 Set |
Payment Terms: | L/C, D/A, D/P, T/T, Western Union |
Supply Ability: | 30 sets per month |
☆ Homogenous temperature linear changing rates: 5℃/min, 10℃/min | ☆ Optional remote-assist service function and teaching CDs. |
☆ Dry air blowing system prevents specimen's surfaces from dewing in rapid temperature change | ☆ Intelligent and high-performance servo refrigerating control technology: energy saving and rapid heating/cooling rate |
☆ 4 load power outlets for specimens with programmable control for protection | ☆ Unique operation mode: make testing area's temperature back ro room temperature after tests are finished |
☆ Special air circulation system inside ensures testing accurancy | ☆ Optonal APP mobility management |
☆ Desig with independent sensors to prevent specimens from damages caused by dewing, overheat, breezeless and smog | ☆ Automatic water supply with ultrapure filter devices; water shortage reminder function(ECS series) |
☆ Special anti-condensation structures design to avoid misjudgment and improve testing accuracy in climate testing | ☆ Strong control abilities of extreme-low humidity range 20℃/10% R.H..(ECS Series) |
Model
|
EC4018
|
EC7018
|
EC4034
|
EC7034
|
EC4060
|
EC7060
|
EC4100
|
EC7100
|
EC4150 |
EC7150
|
Test Space Volume(L)
|
190
|
335
|
600
|
990
|
1540
|
|||||
Temp Test Parameters:
|
||||||||||
Temp. Range (℃)
|
-42/+180 | -72/+180 | -42/+180 | -72/+180 | -45/+180 | -72/+180 | -45/+180 | -73/+180 | -42/+180 | -73/+180 |
Temp. Constancy (℃)
|
±0.1-±0.5 |
|||||||||
Temp. Homogeneity (℃)
|
±0.5-±2.0
|
|||||||||
Heating Rate (℃/min)
|
4.0
|
4.0
|
3.2
|
3.0
|
4.0
|
4.0
|
4.0
|
4.0
|
3.5
|
3.5 |
Cooling Rate (℃/min)
|
4.0
|
3.0
|
4.0
|
3.0
|
3.0
|
2.5
|
3.0
|
2.5
|
2.5
|
2.3 |
Temp. Max. Thermal
Compensation (W)
|
2800
|
1500
|
2800
|
1500
|
1500
|
2500
|
4500
|
3000
|
4200 | 3000 |
Climate Test Parameters:
|
||||||||||
Dewpoint Temp. Range (℃)
|
+4(-3)-+94
10-98
±1.0-±3
±0.1-±0.3
±0.5-±2.0
|
|||||||||
Humid. Range (%RH)
|
||||||||||
Humid.Constancy (%RH)
|
||||||||||
Temp. Constancy (℃)
|
||||||||||
Temp. Homogeneity (℃)
|
||||||||||
Temp and Humid Max.Thermal Compensation (W)
|
400
|
400
|
400
|
400
|
500
|
500
|
500
|
500
|
500
|
500
|
Power
|
AC380V±10%,50HZ,3/N/PE |
Optional Accessories: | Standard Version: |
• Independent sensors for specimen protection(NE60519-2.1993)
• 1 Entry port Φ100mm
|
• 3 Power outlets for specimens • Left and right entry ports Φ50mm • Silicon Stoppers for entry ports • 2 Stainless steel shelves • 1 Water tank with 20L • 1 Water filter |