Detail Information |
|||
Product Name: | High Altitude Test Chamber | Test Space Volume(L): | 1000L |
---|---|---|---|
Test Space Dimension: | 1000mm*1000mm*1000mm | External Dimension: | 1400mm*3250mm*2000mm |
Temperature Range: | -70~150 Degree | Temp. Constancy(℃): | ±0.1-±0.8(Atmospheric Pressure No Load) |
Temp. Homogeneity (℃): | ±0.5-±2.0(Atmospheric Pressure No Load) | Temp. Accuracy(℃): | ±2.0 (Atmospheric Pressure No Load) |
Usage: | High Altitude Test | Pressure Range: | Atmospheric Pressure ~1.0 Atmospheric Pressure ~0.5(Kpa) |
Inner Material: | SUS#304 Stainless Steel | Compressor: | Tecumseh-french |
Controller: | Independent R&D Software | Warranty: | 1 Year |
High Light: | -70 Degree High Altitude Test Chamber,High Altitude Test Chamber,1000L lab humidity chamber |
Product Description
1000L Vacuum Pump Controls High Altitude Test Chamber For Sale
This high altitude test chamber is suitable for simulating environmental tests of high temperature,low temperature,damp heat,low air pressure single climate factor or multiple climatic factors for the whole machine,components and materials.
Temperature Chambers | ETQ7025 | ETQ7050 | ETQ7100 | ETQ7200 |
Climate Chambers | ECQ7025 | ECQ7050 | ECQ7100 | ECQ7200 |
Test Space Volume (L) | 250 | 500 | 1000 | 2000 |
Temp. Test Parameters: | ||||
Temp. Range (℃) | -70~+150 | |||
Temp. Constancy (℃) | ±0.1-±0.8 (Atmospheric Pressure No Load) | |||
Temp. Homogeneity(℃) | ±0.5-±2.0 (Atmospheric Pressure No Load) | |||
Temp. Accuracy (℃) | ±2.0 (Atmospheric Pressure No Load) | |||
Heat Up Time (min) (+ 20℃ to ~150℃) |
60 |
60 |
50 |
60 |
Cooling Down Time (min) (+ 20℃ to~60℃) |
90 |
80 |
60 |
80 |
Pressure Range (Kpa) | Atmospheric Pressure ~1.0 Atmospheric Pressure ~0.5 | |||
Pressure Accuracy (Kpa) | ±2 (Atmospheric Pressure ~40KPa); ±5%(40KPa~4KPa); ±0.1(4KPa~1KPa) | |||
Pressure Release Time (min) |
45(Atmospheric Pressure→1KPa) |
|||
Rapid Release of Pressure Function (optional) |
Pressure Release Range: 75.2KPa → 18.8KPa; Pressure Release Time: 15sec |
|||
Climate Test Parameters for ECQ series: | ||||
Temp. Range (℃) | +10~+95 | |||
Temp.Constancy (℃) |
±0.1~±0.8 (Atmospheric Pressure No Load) |
|||
Temp. Homogeneity (℃) |
±0.1~±2.0 (Atmospheric Pressure No Load) |
|||
Humid. Range (%RH) | (10) 20-98 (Atmospheric Pressure No Load) | |||
Humid. Constancy (%RH) |
±1-±3 (Atmospheric Pressure No Load) |
|||
Test Space Dimension (mm) |
600*600*700 |
800*700*900 |
1000*1000*1000 |
1400W*1200D*1200H |
External Dimension (mm) | 1000*1800*1880 | 1500*2750*1900 | 1400*3250×2000 | 1810W*3710D*2310H |
Power | AC380V±10%, 50HZ, 3/N/PE | |||
Cooling Methods | Water-Cooled |
High Altitude Test chamber Options Accessories |
High Altitude Test chamber Standard Version |
• Iindependent sensors for specimen protection (NE60519-2.1993) |
•1 Set testing electrode |
•Nitrogen gas auxiliary device |
•Electronic temperature and humidity sensors |
•Spare parts package |
|
•E-management and cyber-software |
|
•Video monitor system |
|
•APP for mobility management |
|
•Rapid release of pressure device |
|
•Rapid recovered pressure device |
Enter Your Message