-70 Degree 1000L High Altitude Test Chamber Reliable For Laboratory
Contact Person : Jack He
Phone Number : +86-13842409825
WhatsApp : +8613842409825
Minimum Order Quantity : | 1 | Price : | To Be Negotiated |
---|---|---|---|
Packaging Details : | Wooden packing | Delivery Time : | 30-35 business days after received the payment |
Payment Terms : | L/C, T/T, Western Union | Supply Ability : | 25 per month |
Place of Origin: | China | Brand Name: | Envsin |
---|---|---|---|
Certification: | CE and ISO | Model Number: | ETQ7200 |
Detail Information |
|||
Product Name: | Thermal Vacuum Test Chamber | Application: | Construction Industry |
---|---|---|---|
Test Space Volume (L): | 1000 | Temp. Range (℃): | -70~+150 |
Temp. Constancy (℃): | ±0.1-±0.8 (Atmospheric Pressure No Load) | Temp. Homogeneity(℃): | ±0.5-±2.0 (Atmospheric Pressure No Load) |
Temp. Accuracy (℃): | ±2.0 (Atmospheric Pressure No Load) | Pressure Range (Kpa): | Atmospheric Pressure ~1.0 Atmospheric Pressure ~0.5 |
Pressure Accuracy (Kpa): | ±2 (Atmospheric Pressure ~40KPa); ±5%(40KPa~4KPa); ±0.1(4KPa~1KPa) | Pressure Release Time (min): | 45(Atmospheric Pressure→1KPa) |
High Light: | 150 degree vacuum test chamber,1000L vacuum test chamber,1000L low temperature test chamber |
Product Description
Superior Material Thermal Vacuum Test Chamber Outer Space Thermal Vacuum Test Chamber
The thermal vacuum test chamber is suitable for the machine equipment, spare parts, materials for high temperature, low temperature, damp and hot, depression or more single climate factor climate factor of environmental simulation test, used to evaluate the product or material parts under corresponding temperature, dampand hot, pressure environment on the reliability of the use, storage, transportation, and at the same timefor electrical performance parameters of the test specimen electricity.
Temperature Chambers | ETQ7100 |
Climate Chambers | ECQ7100 |
Test Space Volume (L) | 1000 |
Temp. Test Parameters: | |
Temp. Range (℃) | -70~+150 |
Temp. Constancy (℃) | ±0.1-±0.8 (Atmospheric Pressure No Load) |
Temp. Homogeneity(℃) | ±0.5-±2.0 (Atmospheric Pressure No Load) |
Temp. Accuracy (℃) | ±2.0 (Atmospheric Pressure No Load) |
Heat Up Time (min) (+ 20℃ to ~150℃) |
50 |
Cooling Down Time (min) (+ 20℃ to~60℃) |
60 |
Pressure Range (Kpa) | Atmospheric Pressure ~1.0 Atmospheric Pressure ~0.5 |
Pressure Accuracy (Kpa) |
±2 (Atmospheric Pressure ~40KPa); ±5%(40KPa~4KPa)±0.1(4KPa~1KPa) |
Pressure Release Time (min) |
45(Atmospheric Pressure→1KPa) |
Rapid Release of Pressure Function (optional) |
Pressure Release Range: 75.2KPa → 18.8KPa; Pressure Release Time: 15sec |
Climate Test Parameters for ECQ series: | |
Temp. Range (℃) | +10~+95 |
Temp.Constancy (℃) | ±0.1~±0.8 (Atmospheric Pressure No Load) |
Temp. Homogeneity (℃) | ±0.1~±2.0 (Atmospheric Pressure No Load) |
Humid. Range (%RH) | (10) 20-98 (Atmospheric Pressure No Load) |
Humid. Constancy (%RH) | ±1-±3 (Atmospheric Pressure No Load) |
Test Space Dimension (mm) |
1000W*1000D*1000H |
External Dimension (mm) | 1400W*3250D*2000H |
Power | AC380V±10%, 50HZ, 3/N/PE |
Cooling Methods | Water-Cooled |