Contact Us

Contact Person : Jack He

Phone Number : +86-13842409825

WhatsApp : +8613842409825

Free call

IPX7 Waterproof Test Machine Complies With IEC60529 GB4208 DIN40050-9 ISO20653 Standard

Minimum Order Quantity : 1 Price : To Be Negotiated
Packaging Details : Wooden packing Delivery Time : 30-35 business days after received the payment
Payment Terms : L/C, T/T, Western Union Supply Ability : 25 per month
Place of Origin: China Brand Name: Envsin
Certification: CE and ISO Model Number: BY-IPX7

Detail Information

Product Name: Waterproof Test Chamber Test Standard: IEC60529
Standard: ISO20653 Keyword: Rain Spray Test Chamber
High Light:

IPX7 Waterproof Test Machine

,

IEC60529 Waterproof Test Machine

,

GB4208 Waterproof Tester

Product Description

IPX7 Waterproof test chamber Complies With IEC60529,GB4208,DIN40050-9,ISO20653 Standard

 

The water-proof tester is used for waterproof testing of outer casing protective layers such as electronic electrician and vehicles,

hardware tools and machinery parts, and can provide realistic simulation of electronic products and their components that may be

exposed during transportation and use. Water and spray test and other environments to achieve the waterproof performance of various products. This waterproof test box complies with IEC60529, GB4208, DIN40050-9, ISO20653 and other standards. The test function is

used for product inspection of the enclosure protection class IEC (IP Supplementary Code Enhanced Test), which is manufactured

according to the relevant specifications of DIN40050 standard. Standard enclosure protection rating test method.

 

Brief Despription:

Product name

Waterproof test chamber

Product model

BY-IPX7

Prohibit testing or storage:

Flammable, explosive and volatile substances

Biological specimens with biological characteristics

Specimens with particle radiation and strong electromagnetic interference ability

Specimens that could cause high strength and large proportion of body expansion

Applications:

This immersion test chamber apply to test the immersion of the shell protection layer of electronic and electrical equipment, hardware tools, machinery part, provides a immersive environment in which realistic analog electronic products and their components may be exposed during transportation and us, to achieve the waterproof performance of various products.

This waterproof test chamber complies with IEC60529, GB4208 DIN40050-9, ISO20653. The test function is used for the product inspection of the enclosure protection class IEC (IP Supplementary Code Enhanced Test), which is manufactured according to the relevant specifications of the DIN40050 standard, and meets the relevant standard enclosure protection level test method.

 

Specification:

Main technical parameters

IPX7

The lowest point of the outer casing with a height less than 850mm shall be less than 1000mm below the water surface;

The highest point of the outer casing with a height greater than or equal to 850mm shall be 150mm below the water surface;

Water pressure: 1000kpa; (controller can display)

Test time:30min at least;

Others:size(undetermined)

Test Standard

SO16750-1-2006 environmental conditions and tests for electrical and electronic equipment for road vehicles (general regulations)

DIN40050-9 Shell protection class IP code

ISO20653 road vehicles - degree of protection (IP code) - protection of electrical equipment from foreign objects, water and contact

IEC60529 electrical enclosure protection classification (IP) code

GMW 3172(2007)General requirements for vehicle environment, reliability and performance

VW80106-2008 General test conditions for electrical and electronic components on automobiles

QC/T 417.1(2001)Wiring harness connector for vehicles Part 1

GB4208 Enclosure rating

Rain system

System structure

In order to ensure long-term clean waterway, when the rainwater test is stopped, the water in the water pipe will automatically return to the water tank. The drip tray will be squeezed by compressed air to squeeze out the water, so that there is no water in the water pipe and the drip head to prevent long-term idle. Road water body corruption caused by blockage;

Since the test will generate a large amount of rainwater flow, the rainwater falling from the test will be collected centrally through the overflow port at the bottom of the inner box working chamber, and recycled through the filter.

Drainage floor drain

There are drainage ditch and drainage hole at the bottom of the test box. After the rain test, the accumulated water enters the sedimentation tank and is filtered and used again. The drainage ditch is level with the ground and does not affect the bearing weight of the test box floor and the ingress and exit of test products.

Water pressure flow control method

The closed-loop feedback control system consists of a water pressure sensor, a water flow sensor, a controller, an electromagnetic valve, an AD drive module, a frequency converter, and a water pressure flow regulating pump. The PID control

algorithm is used to dynamically operate the test chamber in real time. The water pressure flow of the chamber nozzle is finely and quickly adjusted. (the image is only a reference)

IPX7 Waterproof Test Machine Complies With IEC60529 GB4208 DIN40050-9 ISO20653 Standard 0

Driver

Digital signal driven stepless inverter, AD drive module (picture is for reference only)

IPX7 Waterproof Test Machine Complies With IEC60529 GB4208 DIN40050-9 ISO20653 Standard 1

Actuator

Use horizontal multi-stage centrifugal water pump with low noise, compact structure and small installation space (image is for reference only)

IPX7 Waterproof Test Machine Complies With IEC60529 GB4208 DIN40050-9 ISO20653 Standard 2

Hydraulic flow sensor

Electronic liquid pressure sensor, electronic liquid flow sensor (image is for reference only)

IPX7 Waterproof Test Machine Complies With IEC60529 GB4208 DIN40050-9 ISO20653 Standard 3

Water nozzle

Special rain drip test nozzle, water spray test nozzle (picture is for reference only)

IPX7 Waterproof Test Machine Complies With IEC60529 GB4208 DIN40050-9 ISO20653 Standard 4

Condensate drain hole

Drainage holes with condensate and condensate in the workshop

Overflow hole

An overflow hole is arranged inside the box to guide the guide water in the test chamber

 

You Might Be Into These
Get in touch with us

Enter Your Message

envsin63@envsin.com
+8613842409825
he
+86-13842409825