Warranty: 12 Months Power: Electronic
Gas Concentration: 5ppm~ 30ppm Gas Flowmeter: H2S,SO2,NO2, CI2
Wind Speed: ≤1.7 M/s
High Light:

Gas Test Chamber

,

Envsin Gas Test Chamber

,

Envsin walk in environmental chamber

Product Description

Product Overviews

25ppm H2S NO2 SO2 Cl2 Gas Corrosion Test Chamber

 

Our service:

 
•provide a complete testing solution (customization)

•Patented and eye-catching industrial design

•Preferential vendor of Apple and Cisco in China

•Perfect systematic pre-sale and after-sale technical support
Stand Type 500l 800l 25ppm H2s Co2 So2 Sulphur Dioxide Gas Corrosion Test Chamber
Application:
Stand Type 500l 800l 25ppm H2s Co2 So2 Sulphur Dioxide Gas Corrosion Test Chamber
Specification
Main Technical Parameters (Product Model:EQF)
Temp test
Temp range:20℃~+45
Remark:
 
1. Test in accordance with GB/T2423 and IEC60068
under empty chamber condition (except indicated).
 
2. The test data of the water-cooled
test chamber are under the conditions that the water
temp is less than 28, the water pressure is between 0.3Mpa and 0.6Mpa, and the
water pressure difference between inlet and outlet is more than 0.2Mpa.
 
Temp uniformity:≤2.0
Temp deviation:≤±2.0
Temp fluctuation:≤±0.5
Temp rate:≥1/min
Temp and humidity test

Humidity temp control range:20~+50

Humidity range:50%RH~85%RH

Humidity uniformity:±5.0%RH
Humidity deviation: +2.0%~3%RH(>75%RH)±5%R.H(≤75%RH)
Humidity fluctuation:±5.0%RH
Gas concentration 5ppm~30ppm
The deviation of gas concentration in the chamber shall not exceed 10% of the set concentration,Concentration uniformity deviation of 10%
The empty chamber operation request meets the IEC60068-2-60 standard
Gas concentration measurement By calculating the volume ratio and then through the mass flowmeter measurement
On load capacity
500W,The temp can be stable, the chamber body is not deformed
Noise
Working noise ≤70dB (measured at 1 meter away from the test chamber)
Wind speed
≤1.7m/s
Gas flowmeter H2S,SO2,NO2,CI2
Standard

 

GB/T 2423.1-2001 / (IEC60068-2-1:2007) Test A: Low temp test method

GB/T 2423.2-2001 / (IEC60068-2-2:2007) Test B: High temp test method

 

GB/T 2423.3-2006 / (IEC60068-2-78:2007) Test Cab: Constant humidity and heat test
GB/T 2423.4-2008 / (IEC60068-2-30:2005) Test Db: alternating humidity and heat test
GJB 150.3-1986 / GJB 150.3A-2009 High-temp test
GJB 150.4-1986 / GJB 150.4A-2009 Low temp test
GJB 150.9-1986 / GJB 150.9A-2009 Thermal-humidity test

 

IEC60068-2-60 Test Method KE: Man-made low concentration pollution gas corrosion test

 
GB/T2423.51-2000 Environmental testing of electrical and electronic products Test KE: Flow mixed gas corrosion test
Quality Control

Stand Type 500l 800l 25ppm H2s Co2 So2 Sulphur Dioxide Gas Corrosion Test Chamber

Multipurpose Envsin Gas Test Chamber , Walk In Environmental Chamber Electronic 3

You Might Be Into These
Get in touch with us

Enter Your Message

envsin61@envsin.com
+8613842409825
he
+86-13842409825
+86-13842409825