Send Message
Contact Us

Contact Person : Jack He

Phone Number : +86-13842409825

WhatsApp : +8613842409825

Free call

Low-Pressure Simulation 0.5Kpa 1Kpa -70℃~150℃ with Humidity

Minimum Order Quantity : 1 Packaging Details : Woden Case
Delivery Time : 2Months~3Months Payment Terms : Western Union, T/T
Place of Origin: China Brand Name: Envsin
Certification: CE Model Number: EQT

Detail Information

Product Name: Altitude Test Chamber Model Number: ETQ7200
Product Color: White Bule Usage: Widely Range
Pressure Range: Atmospheric Pressure~ 1.0Kpa,0.5Kpa Test Space Volume: 2000L
Highlight:

380V high low temperature test chamber

,

2000L high low temperature test chamber

,

2000L walk in environmental test chambers

Product Description

Low-Pressure Simulation 0.5Kpa 1Kpa -70℃~150℃ with Humidity

A Temperature, Humidity, and Low Pressure Test Chamber is designed to simulate harsh environmental conditions by testing the combined effects of extreme temperatures, humidity, and low atmospheric pressure on products, materials, and components. This chamber helps to evaluate how items perform under extreme conditions that may occur during their transportation, storage, or use, especially at high altitudes or in space-like environments. The chamber’s ability to control temperature, humidity, and pressure allows for comprehensive testing to ensure the durability, reliability, and safety of various products.

 

 

Applications:

  1. Aerospace and Aviation: Widely used in aerospace for testing components like sensors, electronic devices, and materials, simulating conditions experienced during flight at high altitudes and space missions.
  2. Automotive Industry: Tests the performance of automotive parts (such as sensors, electrical systems, and seals) under extreme weather, altitude, and pressure conditions, ensuring their durability and reliability.
  3. Electronics and Electrical Components: Essential for testing the durability of electrical equipment, such as circuit boards, batteries, and semiconductor devices, under high/low temperatures, humidity, and low-pressure environments.
  4. Military and Defense: Used for evaluating equipment like communication systems, navigation instruments, and protective gear, ensuring they perform in extreme weather and pressure conditions.
  5. Medical Devices: Assists in testing medical equipment and devices, ensuring they function correctly under a range of environmental conditions that may be encountered in high-altitude or extreme climates.
  6. Consumer Goods Testing: For products like outdoor equipment, sporting goods, and packaging, it ensures reliability under environmental extremes during use or transport.
  7. Pharmaceutical and Food Industry: Testing packaging materials, medications, and food products for durability and stability in varying environmental conditions.


Low-Pressure Simulation 0.5Kpa 1Kpa -70℃~150℃ with Humidity 0Low-Pressure Simulation 0.5Kpa 1Kpa -70℃~150℃ with Humidity 1Low-Pressure Simulation 0.5Kpa 1Kpa -70℃~150℃ with Humidity 2Low-Pressure Simulation 0.5Kpa 1Kpa -70℃~150℃ with Humidity 3

Parameters

Temperature Chambers                      Climate Chambers ETQ7025 ETQ7050 ETQ7100 ETQ7200
ECQ7025 ECQ7050 ECQ7100 ECQ7200
Test Space Volume (L) 250 500 1000 2000
Temp. Test Parameters:
Temp. Range (℃) -70~+150
Temp.Constancy (℃) ±1.0 ~ ±0.8 (Atmospheric Pressure No Load)
Temp. Homogeneity (℃) ±0.5 ~ ±2.0 (Atmospheric Pressure No Load)
Temp. Accuracy (℃) ±2.0 (Atmospheric Pressure No Load)
Heat Up Time (min) (+20℃ to~150℃) 60 60 50 60
Cooling Down Time (min) (+20℃ to~60℃) 90 80 60 80
Pressure Range (Kpa) Atmospheric Pressure~ 1.0 Atmospheric Pressure ~ 0.5
Pressure Accuracy (Kpa) ±2.0 (Atmospheric Pressure~ 40Kpa);±5%(40KPa~4KPa);±0.1(4KPa~1KPa)
Pressure Release Time (min) 45(Atmospheric Pressure→1KPa)
Rapid Release of Pressure Function (Optional) Pressure Release Range:75.2KPa →18.8KPa; Pressure Release Time:15sec
Climate Test Parameters for ECQ series:
Temp. Range (℃) +10 ~ +95
Temp. Constancy (℃) ±1.0 ~ ±0.8 (Atmospheric Pressure No Load)
Temp. Homogeneity (℃) ±1.0 ~ ±2.0 (Atmospheric Pressure No Load)
Humid. Range (%RH) (10) 20 ~ 98 (Atmospheric Pressure No Load)
Humid. Constancy (%RH) ±1.0 - ±3.0 (Atmospheric Pressure No Load)
Test Space Dimension (mm) 600W×600D×700H 800W*700D*900H 1000W×1000D×1000H 1400W*1200D*1200H
External Dimension (mm) 1000W×1800D×1800H 1500W*2750D*1900H 1400W×3250D×2000H 1810W*3710D*2310H
Power AC380V±10%,50HZ,3/N/PE
Cooling Methods Water-Cooled

 

Options Standard Version
APP for mobility management 1 Set testing electrode
Independent sensors for specimen protection (NE60519-2.1993) Electronic temperature and humidity sensors
1 Entry port Φ50mm  
Nitrogen gas auxiliary device  
Spare parts package  
E-management and cyber-software  
Rapid release of pressure device  
Video monitor system  
Rapid recovered pressure device  

Low-Pressure Simulation 0.5Kpa 1Kpa -70℃~150℃ with Humidity 4

 

 

 