-70 Degree 1000L Programmable Altitude Test Chamber for Electronics Reliability Testing
Contact Person : Jack He
Phone Number : +86-13842409825
WhatsApp : +8613842409825
Detail Information |
|||
Name: | Temperature, Humidity, And Low Pressure Test Chamber | Cooling Methods: | Water-Cooled |
---|---|---|---|
Power: | Electronic | Power Supply: | AC220V 50HZ |
Temperature Range:: | -70℃~150 ℃ | Certification: | CE |
Highlight: | 220V High Pressure Test Chamber,250L high pressure test chamber,220V space simulation vacuum chamber |
Product Description
Temperature, Humidity, and Low Pressure Test Chamber
A Temperature, Humidity, and Low Pressure Test Chamber is designed to simulate harsh environmental conditions by testing the combined effects of extreme temperatures, humidity, and low atmospheric pressure on products, materials, and components. This chamber helps to evaluate how items perform under extreme conditions that may occur during their transportation, storage, or use, especially at high altitudes or in space-like environments. The chamber’s ability to control temperature, humidity, and pressure allows for comprehensive testing to ensure the durability, reliability, and safety of various products.
Key Features:
Applications:
Specifications
Temperature Chambers Climate Chambers | ETQ7025 | ETQ7050 | ETQ7100 | ETQ7200 |
ECQ7025 | ECQ7050 | ECQ7100 | ECQ7200 | |
Test Space Volume (L) | 250 | 500 | 1000 | 2000 |
Temp. Test Parameters: | ||||
Temp. Range (℃) | -70~+150 | |||
Temp.Constancy (℃) | ±1.0 ~ ±0.8 (Atmospheric Pressure No Load) | |||
Temp. Homogeneity (℃) | ±0.5 ~ ±2.0 (Atmospheric Pressure No Load) | |||
Temp. Accuracy (℃) | ±2.0 (Atmospheric Pressure No Load) | |||
Heat Up Time (min) (+20℃ to~150℃) | 60 | 60 | 50 | 60 |
Cooling Down Time (min) (+20℃ to~60℃) | 90 | 80 | 60 | 80 |
Pressure Range (Kpa) | Atmospheric Pressure~ 1.0 Atmospheric Pressure ~ 0.5 | |||
Pressure Accuracy (Kpa) | ±2.0 (Atmospheric Pressure~ 40Kpa);±5%(40KPa~4KPa);±0.1(4KPa~1KPa) | |||
Pressure Release Time (min) | 45(Atmospheric Pressure→1KPa) | |||
Rapid Release of Pressure Function (Optional) | Pressure Release Range:75.2KPa →18.8KPa; Pressure Release Time:15sec | |||
Climate Test Parameters for ECQ series: | ||||
Temp. Range (℃) | +10 ~ +95 | |||
Temp. Constancy (℃) | ±1.0 ~ ±0.8 (Atmospheric Pressure No Load) | |||
Temp. Homogeneity (℃) | ±1.0 ~ ±2.0 (Atmospheric Pressure No Load) | |||
Humid. Range (%RH) | (10) 20 ~ 98 (Atmospheric Pressure No Load) | |||
Humid. Constancy (%RH) | ±1.0 - ±3.0 (Atmospheric Pressure No Load) | |||
Test Space Dimension (mm) | 600W×600D×700H | 800W*700D*900H | 1000W×1000D×1000H | 1400W*1200D*1200H |
External Dimension (mm) | 1000W×1800D×1800H | 1500W*2750D*1900H | 1400W×3250D×2000H | 1810W*3710D*2310H |
Power | AC380V±10%,50HZ,3/N/PE | |||
Cooling Methods | Water-Cooled |
Options | Standard Version |
☆ APP for mobility management | ☆ 1 Set testing electrode |
☆ Independent sensors for specimen protection (NE60519-2.1993) | ☆ Electronic temperature and humidity sensors |
☆ 1 Entry port Φ50mm | |
☆ Nitrogen gas auxiliary device | |
☆ Spare parts package | |
☆ E-management and cyber-software | |
☆ Rapid release of pressure device | |
☆ Video monitor system | |
☆ Rapid recovered pressure device |