High Precision IEC Standard AC 380V Gas Test Chamber Stainless Steel
Contact Person : Jack He
Phone Number : +86-13842409825
WhatsApp : +8613842409825
Detail Information |
|||
Humidity Range: | 0%RH~85%RH | Temp. Uniformity: | ≤2.0℃ |
---|---|---|---|
Humidity Uniformity: | ±5.0%RH | Humidity Fluctuation: | ±5.0%RH |
Certification: | CE | Warranty: | 12 Months |
High Light: | H2S laboratory test chamber,CE laboratory test chamber,SO2 gas sensor test chamber |
Product Description
SO2 H2S CO2 HCL Corrosion Noxious Gas Test Chamber For Laboratory
Features
★Fashionable design of modular construction
★7 colors touch screen display and 3 bit control system;interface Ethernet/USB
★Special air circulation system inside ensures testing accuracy.(Patented)
★Optional network video monitoring and data synchronization
★Automatic reminder of equipment maintenance plans and software of recording malfunction
★Optional remote-assist service function and teaching CDs
★Optional APP mobility management
Technical Parameters
Temperature test | Temperature range:20℃~+45℃ | Remark: 1. Test in accordance with GB/T2423 and IEC60068 under empty chamber condition (except indicated). 2. The test data of the water-cooled test chamber are under the conditions that the water temperature is less than 28, the water pressure is between 0.3Mpa and 0.6Mpa, and the water pressure difference between inlet and outlet is more than 0.2Mpa. |
Temperature uniformity:≤2.0℃ | ||
Temperature deviation:≤±2.0℃ | ||
Temperature fluctuation:≤±0.5℃ | ||
Temperature rate:≥1℃/min | ||
Temperature and humidity climatic test | Humidity temperature control range:20℃~+50℃ | |
Humidity range:50%RH~85%RH | ||
Humidity uniformity:±5.0%RH | ||
Humidity deviation: +2.0%~3%RH(>75%RH)±5%R.H(≤75%RH) | ||
Humidity fluctuation:±5.0%RH | ||
Gas concentration | 5ppb~30ppm | |
The deviation of gas concentration in the chamber shall not exceed 10% of the set concentration,Concentration uniformity deviation of 10% | ||
The empty chamber operation request meets the IEC60068-2-60 standard | ||
Gas concentration measurement | By calculating the volume ratio and then through the mass flowmeter measurement | |
On load capacity | 500W,The temperature can be stable, the chamber body is not deformed | |
Noise | Working noise ≤70dB (measured at 1 meter away from the test chamber) | |
Wind speed | ≤1.7m/s | |
Gas flowmeter | H2S,SO2,NO2,CI2 | |
Standard | GB/T 2423.1-2001 / (IEC60068-2-1:2007) Test A: Low temperature test method | |
GB/T 2423.2-2001 / (IEC60068-2-2:2007) Test B: High temperature test method | ||
GB/T 2423.3-2006 / (IEC60068-2-78:2007) Test Cab: Constant humidity and heat test | ||
GB/T 2423.4-2008 / (IEC60068-2-30:2005) Test Db: alternating humidity and heat test | ||
GJB 150.3-1986 / GJB 150.3A-2009 High-temperature test | ||
GJB 150.4-1986 / GJB 150.4A-2009 Low temperature test | ||
GJB 150.9-1986 / GJB 150.9A-2009 Thermal-humidity test | ||
IEC60068-2-60 Test Method KE: Man-made low concentration pollution gas corrosion test | ||
GB/T2423.51-2000 Environmental testing of electrical and electronic products Test KE: Flow mixed gas corrosion test |