Contact Us

Contact Person : Jack He

Phone Number : +86-13842409825

WhatsApp : +8613842409825

Free call

OEM Available SO2 Gas Test Machine For Testing Automotive Components

Minimum Order Quantity : 1 Payment Terms : T/T, Western Union
Place of Origin: China Brand Name: Envsin
Certification: CE Model Number: EQF

Detail Information

Chamber Name: Gas Corrosion Test Chamber Customized: OEM And ODM
Wind Speed (m/s): ≤1.7 Gas Flowmeter: H2S,SO2,NO2
Temperature Rate: ≥1℃/min Humidity Uniformity: ±5.0%RH
High Light:

OEM gas test machine

,

SO2 gas test machine

,

OEM so2 test chamber

Product Description

H 2 S SO 2 Gas Corrosion Test Chamber for testing automotive components

This test chamber allow to determine the corrosive effect of the woring and storage envirnoment on electrotechnical components, it can be used for single gas and mixed gas test. the methods apply with IEC60068-2-42 and others.

 

OEM Available SO2 Gas Test Machine For Testing Automotive Components 0

Technical Parameters

Temperature test Temperature range:20℃~+45℃ Remark:

1. Test in accordance with GB/T2423 and IEC60068 under empty chamber condition (except indicated).

2. The test data of the water-cooled
test chamber are under the conditions that the water temperature is less than 28, the water pressure is between 0.3Mpa and 0.6Mpa, and the water pressure difference between inlet and outlet is more than 0.2Mpa.
Temperature uniformity:≤2.0℃
Temperature deviation:≤±2.0℃
Temperature fluctuation:≤±0.5℃
Temperature rate:≥1℃/min
Temperature and humidity climatic test Humidity temperature control range:20℃~+50℃
Humidity range:50%RH~85%RH
Humidity uniformity:±5.0%RH
Humidity deviation: +2.0%~3%RH(>75%RH)±5%R.H(≤75%RH)
Humidity fluctuation:±5.0%RH
Gas concentration 5ppb~30ppm
The deviation of gas concentration in the chamber shall not exceed 10% of the set concentration,Concentration uniformity deviation of 10%
The empty chamber operation request meets the IEC60068-2-60 standard
Gas concentration measurement By calculating the volume ratio and then through the mass flowmeter measurement
On load capacity 500W,The temperature can be stable, the chamber body is not deformed
Noise Working noise ≤70dB (measured at 1 meter away from the test chamber)
Wind speed ≤1.7m/s
Gas flowmeter H2S,SO2,NO2,CI2
   
Standard  (IEC60068-2-1:2007) Test A: Low temperature test method
 
 (IEC60068-2-2:2007) Test B: High temperature test method
 
 (IEC60068-2-78:2007) Test Cab: Constant humidity and heat test
 
 (IEC60068-2-30:2005) Test Db: alternating humidity and heat test
 
GJB 150.3-1986 / GJB 150.3A-2009 High-temperature test
 
GJB 150.4-1986 / GJB 150.4A-2009 Low temperature test
 
GJB 150.9-1986 / GJB 150.9A-2009 Thermal-humidity test
 
IEC60068-2-60 Test Method KE: Man-made low concentration pollution gas corrosion test
 
GB/T2423.51-2000 Environmental testing of electrical and electronic products Test KE: Flow mixed gas corrosion test

 